Meaning
Repeatability is how closely repeated measurements or positions agree under the same conditions, as distinct from how close they come to the true value. It is the figure instrument makers publish most often. A small repeatability says the instrument is consistent, while calibration and the machine’s state decide whether it is right.Published Figure
Renishaw gives its RMP60 probe a unidirectional repeatability of 1.00 µm (40 µin) at two standard deviations. The figure holds at 480 mm/min (18.9 in/min) with a 50 mm (1.97 in.) stylus. A longer stylus, another speed or a cranked stylus can change it, and the sheet says repeatability at other conditions may differ. Trigger force also depends on measuring speed, machine deceleration and latency. Where a probe’s shank relocates poorly in the spindle, Renishaw’s manual recalibrates it each time it is selected.Read More
Gauge R&R
A gauge has to repeat before its readings can be compared with a tolerance. Lockheed Martin UK’s guidebook points to gauge repeatability and reproducibility studies as the proof that equipment can be trusted. Where it rejects an instrument, the reviewer lacked confidence in a valid, repeatable and reproducible measurement.Against Drift
A probe’s 1 µm (0.00004 in.) repeatability is small beside thermal drift of tens of micrometers. A ball screw grew more than 110 µm (0.0043 in.) in 40 minutes in HEIDENHAIN’s test. The datum is therefore re-checked at intervals, with the interval set by the drift test for that machine. That test itself rests on repeated positioning to two points near the ends of the axis, read until the drift levels off.