DrawingGaugeCoating

ISO 965 6H Tolerance for Tapped Holes in Machined Metal

A 6H tapped hole has a band measured in hundredths of a millimeter, and a coating can use up most of it before the part is checked.

A machined steel block with a row of clean tapped threaded holes, bright crisp threads, and plain steel thread plug gauges with knurled handles standing beside it, every surface unmarked.

The pitch diameter of an M6 × 1 internal thread to class 6H is allowed to sit anywhere between 5.350 mm and 5.500 mm, a band 0.150 mm (0.0059 in.) wide. A Type II anodic coating 0.0004 in. (10 µm) thick closes the hole by four times its surface growth on a 60 degree thread, which is 20 µm, a seventh of that band. A hard coat of 0.002 in. (51 µm) closes it by 102 µm, two thirds of it.

Those two numbers come from two different documents, ISO 965 for the thread and MIL-A-8625 for the coating, and a drawing that cites both without reconciling them leaves the shop to settle a collision at the machine. The thread standard is short on rules and long on tables. This article reads the part of it that governs a tapped hole in a machined metal part: how the class is written, what 6H means in millimeters and inches for common sizes, how the limits are checked, and how a coating changes the answer.

What 6H Means on a Drawing

ISO 965-1 sets the system for ISO general purpose metric screw threads. A tolerance class is written as a figure for the tolerance grade followed by a letter for the tolerance position, a capital letter for an internal thread and a small letter for an external one. A fit between threaded parts is written as the internal class, then a stroke, then the external class, for example M6 – 6H/6g.

The grade says how wide the band is, and the position says where it sits relative to the basic size. The system provides grades 4 to 8 for the minor diameter D1 of an internal thread and for its pitch diameter D2, and positions G and H for internal threads. Grade 6 is the one the standard assigns to tolerance quality medium and normal length of thread engagement, grades below 6 to fine quality or short engagement, and grades above 6 to coarse quality or long engagement.

M6 on a drawing, with no class stated, already means 6H for the nut thread and 6g for the screw. The standard defines the default for sizes of M1.6 and larger.

The Default When Nothing Is Written

The standard states that the absence of a tolerance class designation means quality medium. That is 6H for internal threads of M1.6 and larger, and 5H up to and including M1.4. For external threads it is 6g from M1.6 and 6h below. The length of engagement is taken as normal, group N, unless an S for short or an L for long is added after a dash, as in M6 – 7H/7g6g – L. A drawing for a tapped hole that says only “M6” or “M6 × 1 – 6H” therefore specifies the same thing.

6H Limits of Size for Common Tapped Holes

ISO 965-2 gives the limits of size for tolerance classes 6H and 6g for M1.6 to M100 and 5H and 6h for M1 to M1.4. The tables below are from the public preview of the 2024 edition, which prints the internal thread table in full for the smaller sizes. The pitch diameter tolerance and the minor diameter tolerance in the fourth and sixth columns are the differences between the printed maximum and minimum.

Table 1. ISO 965-2:2024 limits of size for internal threads, class 6H, normal length of engagement, in mm with the tolerance band in micrometers and inches
Thread Pitch diameter D2, max to min D2 band Minor diameter D1, max to min D1 band Normal engagement length
M3 × 0.5 2.775 to 2.675 100 µm (0.0039 in.) 2.599 to 2.459 140 µm (0.0055 in.) 1.5 to 4.5 mm
M4 × 0.7 3.663 to 3.545 118 µm (0.0046 in.) 3.422 to 3.242 180 µm (0.0071 in.) 2 to 6 mm
M5 × 0.8 4.605 to 4.480 125 µm (0.0049 in.) 4.334 to 4.134 200 µm (0.0079 in.) 2.5 to 7.5 mm
M6 × 1 5.500 to 5.350 150 µm (0.0059 in.) 5.153 to 4.917 236 µm (0.0093 in.) 3 to 9 mm
M8 × 1.25 7.348 to 7.188 160 µm (0.0063 in.) 6.912 to 6.647 265 µm (0.0104 in.) 4 to 12 mm
M10 × 1.5 9.206 to 9.026 180 µm (0.0071 in.) 8.676 to 8.376 300 µm (0.0118 in.) 5 to 15 mm
M12 × 1.75 11.063 to 10.863 200 µm (0.0079 in.) 10.441 to 10.106 335 µm (0.0132 in.) 6 to 18 mm
M16 × 2 14.913 to 14.701 212 µm (0.0083 in.) 14.210 to 13.835 375 µm (0.0148 in.) 8 to 24 mm

Three things stand out. The pitch diameter band grows slowly with the size, from 100 µm at M3 to 212 µm at M16, while the minor diameter band is about 1.4 to 1.8 times wider than the pitch diameter band at every size. And the engagement length for which 6H is defined runs from half the nominal diameter to one and a half times it.

Which Drill Fits Inside the Minor Diameter Band

The hole that is drilled before tapping is the minor diameter of the finished thread, so the drill diameter has to land inside the D1 window. Checking the preferred sizes against Table 1 shows how much room each leaves.

  • M3 × 0.5, drill 2.5 mm, inside 2.459 to 2.599 mm, with 0.041 mm above the minimum and 0.099 mm under the maximum.
  • M6 × 1, drill 5.0 mm, inside 4.917 to 5.153 mm, with 0.083 mm above the minimum and 0.153 mm under the maximum.
  • M8 × 1.25, drill 6.8 mm, inside 6.647 to 6.912 mm.
  • M10 × 1.5, drill 8.5 mm, inside 8.376 to 8.676 mm.
  • M12 × 1.75, drill 10.2 mm, inside 10.106 to 10.441 mm.

Those drill sizes are conventional tapping drills and they all fit the 6H windows, which is a check from arithmetic and not a statement of the standard. A drilled hole that runs oversize by one or two hundredths of a millimeter is still inside the band, while a drill that wears below the lower limit removes too little metal and leaves more for the tap to cut.

Positions G and H and the Allowance Under a Coating

Position H has zero fundamental deviation, so the minimum pitch diameter of a 6H thread is the basic pitch diameter itself, with the band above it. Position G has a positive fundamental deviation, which moves the whole band outward. The corresponding external positions e, f and g carry negative deviations, and h has none.

Table 2. Fundamental deviations in µm for internal and external threads by pitch, ISO 965-1:1998 Table 1, with inch in brackets for the pitches of the sizes in Table 1
Pitch P Internal G (EI) Internal H (EI) External e (es) External f (es) External g (es) External h (es)
0.5 mm +20 (0.0008 in.) 0 −50 −36 −20 0
0.75 mm +22 (0.0009 in.) 0 −56 −38 −22 0
1 mm +26 (0.0010 in.) 0 −60 −40 −26 0
1.25 mm +28 (0.0011 in.) 0 −63 −42 −28 0
1.5 mm +32 (0.0013 in.) 0 −67 −45 −32 0
1.75 mm +34 (0.0013 in.) 0 −71 −48 −34 0
2 mm +38 (0.0015 in.) 0 −71 −52 −38 0

The standard says the positions were set to comply with the need for current coating thickness and with the demands of easy assembly. The practical reading is that the external g position, the one 6g uses, leaves 26 µm of clearance at a 1 mm pitch before any tolerance is counted, which is a built-in allowance for a thin coat on a bolt. The internal H position leaves nothing on the nut side.

What ISO 965-2 Says About Coated Threads

For coated threads, ISO 965-2 states that the tolerance classes apply to the parts before coating, unless otherwise stated. After coating, the actual thread profile shall not at any point exceed the maximum material limit for tolerance position H or h. When the maximum, or a lower, torque is applied, the GO thread plug gauge has to pass through the coated internal thread or the GO ring gauge over the coated external thread. The standard adds that its provisions are intended for thin coatings, for instance those obtained by electroplating.

The standard checks a coated thread with a GO gauge. It does not say what a thick coating does to the pitch diameter, and an anodic coating on a tapped hole is a thick coating.

A Coating Takes Its Share of the Band

MIL-A-8625F gives the growth of an anodic coating as half its thickness on each surface, and states that on a 60 degree thread the pitch diameter increases by four times the growth, with the major and minor diameters increasing by twice the growth. For an internal thread, growth into the hole is a loss of size, so the pitch diameter band is eaten from the minimum-size end.

Table 3. Share of the 6H pitch diameter band consumed by an anodic coating, from the MIL-A-8625F growth rules and the ISO 965-2 bands of Table 1
Coating Pitch diameter change M6 × 1, band 150 µm M10 × 1.5, band 180 µm
Type II, 0.0004 in. (10 µm) 20 µm (0.0008 in.) 13 % 11 %
Type II, 0.0010 in. (25 µm) 51 µm (0.0020 in.) 34 % 28 %
Type III, 0.002 in. (51 µm) 102 µm (0.0040 in.) 68 % 57 %
Type III, 0.004 in. (102 µm) 203 µm (0.0080 in.) 135 % 113 %

The last row has no answer within the standard’s classes. A hard coat 0.004 in. thick on an M6 tapped hole closes the pitch diameter by more than the full 6H band, so a hole cut anywhere inside 6H before coating ends up past its maximum material limit. MIL-A-8625F’s own remarks apply: both a machining dimension and a coated dimension should appear on the drawing, and the document warns of interference in close fits, especially with Type III.

Two measures come out of the table. A tapped hole that has to be coated is cut at the upper end of the pitch diameter band, so that the coating’s growth consumes the margin and not the part, or it is cut to a position G thread, which moves the whole band outward. And a hole that has to hold its thread unplated can be masked, which is a request the drawing makes in words.

Holes and Small Threads Under Anodizing

MIL-A-8625F adds that in small holes and tapped holes the coating thickness can vary from no film to a full normal coating, and that holes over 1/4 in. (6.35 mm) should be anodized. It also says that the designer is cautioned to require adequate thread and hole sealing in subsequent assemblies where necessary for the corrosion resistance. For an M6 hole, at 6 mm just under that size, the document’s advice does not settle whether it receives a coating, and the drawing has to state it. A thread needs wall to hold it, which is why a bracket made by laser cutting and bending from thin sheet usually carries its threads in pressed-in nuts, while a thicker machined part carries them in its own material to the 6H band described here.

How a Tapped Hole Is Checked

The standard’s checking statement in the preview is the GO gauge: a plug gauge that passes through the finished and coated internal thread when the specified torque is applied. A plug gauge answers one question, whether the thread is at or inside its maximum material limit, and the preview does not reproduce the NO-GO rules. A buyer who wants a pitch diameter measurement, in micrometers and not a pass or fail, asks for it on the inspection plan, and the shop names the method.

Length of engagement matters to the check, because the tolerance table is defined for the normal group. For an M6 × 1 thread, the normal group runs from 3 to 9 mm. A tapped hole 12 mm deep is in the long group, for which the standard recommends coarser grades, and a drawing that writes M6 – 6H for such a hole has chosen a quality the standard did not set for that length. An L added after the class, as in 7H – L, is how the standard names it.

Blind Holes and the Bottom Thread

A blind hole is drilled deeper than its thread, and the tap has a lead of several pitches at its tip, so the full thread does not reach the bottom. The preview does not state how much of a blind hole carries full thread, and the figure depends on the tap. The drawing states the depth of full thread and not only the depth of the hole.

A Thread Note That Settles the Questions

Pulling the points above together gives a note that leaves little to interpretation. For an M6 tapped hole in a part that is anodized, the note names the thread and class, the length of engagement, the depth of full thread, the coating and what happens to the thread inside it.

  • Thread and class, for example M6 × 1 – 6H, with the class written even though it is the default.
  • Engagement, normal unless a drawing adds S or L, and the depth of full thread in millimeters.
  • Coating, the type and class from MIL-A-8625, with the thickness for Type III.
  • Thread treatment, whether the hole is masked, coated and gauged after coating, or tapped after coating.
  • Gauge, a GO plug on the finished part at least, with any other inspection named.

A hole tapped after the coating is cut in coated metal, so it escapes the growth calculation altogether and takes the thread limits of Table 1 directly. That choice moves the burden to the tap, which then cuts through an anodic layer that is harder than the base metal, as MIL-A-8625F notes of all anodic coatings. The standard governs neither choice, and the drawing has to make it.

What a Supplier Signs and What Remains Open

A supplier who accepts M6 – 6H signs the limits of Table 1 for the size, taken before any coating, and a GO gauge check. The standard leaves open the coating, the engagement group, the gauge for the other limit, and whether the thread is cut or formed. For parts that move from a first article toward a short run, a buyer plans the hole, the tap, the coating and the gauge together, and can read about low-volume metal CNC and about bridge production before releasing the drawing.

Sources and Further Reading

Request a Metal CNC Quote

Send the 2D drawing and the 3D file, with the quantity and the stage of the project. An engineer replies within 1 working day.

The quote form, the mutual NDA and the private folder for your files are on Protolis Atelier, with Metal CNC chosen.

Request a Quote