MIL-A-8625

MIL-A-8625 is the US Department of Defense specification for anodic coatings on aluminum and aluminum alloys, defined by type and class.

Every MIL-A-8625 article of the Metal CNC Resources, newest first, each written from published standards, research and makers’ data.

Meaning

MIL-A-8625 is the US Department of Defense specification for anodic coatings on aluminum and aluminum alloys, defined by type and class. It is the standard most often written on a drawing for anodized aluminum, as a line such as “Type II, Class 2”. Its design notes near the end hold the rules that move a machined part’s size.

Edition

The text opened for these resources is revision F of 10 September 1993, released for public distribution. Later amendments and revisions exist, so a purchase order names the revision it means.
Read More

Weight or Thickness

Types I, IB, IC, II and IIB are bought by coating weight, tested before dyeing or sealing. Type II carries a minimum of 10.8 g/m² (1000 mg/ft²). Type III is bought by thickness, with a default of 0.051 mm (0.002 in.) and a tolerance of ±20 % up to that thickness.

Acceptance Tests

Corrosion specimens face 336 hours of 5 % salt spray to ASTM B117, inclined 6 degrees from vertical. Unsealed Type III has a wear index limit of 3.5 mg per 1000 cycles on alloys with 2 % copper or more. On all other alloys the limit is 1.5 mg.

Design Notes

A coating grows by half its thickness on each surface. The pitch diameter of a 60 degree thread grows by four times that growth. Edges and inside corners are radiused, by about 1.6 mm (1/16 in.) under a 51 µm (0.002 in.) coating. The thicker the coating, the greater the loss of fatigue strength.

Against Passivation

An anodized coating is proved by its weight, thickness and salt spray hours. A passivator under ASTM A967 proves a surface by a test that shows no free iron, and adds no layer to the part.

ASTM B117 Salt Spray Testing of Anodized and Plated Machined Parts

B117 sets the fog but not the hours, specimens or pass mark, so the order has to name the coating specification, the rating method and what was tested.

What ASTM B117 Controls and What It Leaves to the OrderASTM B117 is a practice for operating an apparatus. Its scope covers the equipment, the procedure and the conditions needed to create and keep a salt fog environment, and the apparatus it describes sits in an appendix.

ISO 965 6H Tolerance for Tapped Holes in Machined Metal

A 6H tapped hole has a band measured in hundredths of a millimeter, and a coating can use up most of it before the part is checked.

What 6H Means on a DrawingISO 965-1 sets the system for ISO general purpose metric screw threads. A tolerance class is written as a figure for the tolerance grade followed by a letter for the tolerance position, a capital letter for an internal thread and a small letter for an external one.

MIL-A-8625 Anodizing Types and Classes for Machined Aluminum

MIL-A-8625 names the bath, color state, weight or thickness and sealing of an anodized coating, and each choice moves the size of a machined part.

What MIL-A-8625 Covers and What the Types MeanRevision F covers six types and two classes of electrolytically formed anodic coatings on aluminum and aluminum alloys for non-architectural uses. The types differ by the bath and the weight of the coating: Type I is conventional chromic acid anodizing, Type IB a low-voltage chromic acid process, Type IC a non-chromic acid process offered as a non-chromate alternative, Type II conventional sulfuric acid anodizing, Type IIB a thin sulfuric acid process that is also a non-chromate alternative, and Type III the hard anodic coating.

ASTM A967 Passivation for Machined Stainless Steel Parts

ASTM A967 names the baths and the lot tests for passivated stainless parts, and the drawing has to name the treatment, test and edition it wants.

What ASTM A967 Covers and What It Does NotASTM A967/A967M covers chemical passivation treatments for stainless steel parts, along with recommendations and precautions for descaling, cleaning and passivating. The abstract names three families of treatment: immersion in a nitric acid solution, immersion in a citric acid solution, and an electrochemical treatment.

Request a Metal CNC Quote

Send the 2D drawing and the 3D file, with the quantity and the stage of the project. An engineer replies within 1 working day.

The quote form, the mutual NDA and the private folder for your files are on Protolis Atelier, with Metal CNC chosen.