Meaning
A gauge is an instrument that checks a size against its limits, either by reading a value or by fitting or refusing to fit. A reading gauge, such as a dial or height gauge, returns a number. A fixed gauge, such as a thread plug gauge, returns a pass or a fail at one limit. Which kind the inspection plan names decides whether a report can show how close a part came to its limit.Common Forms
The burr study in these resources measured burr height with a mechanical height gauge of 13 µm (0.0005 in.) sensitivity. Each condition was drilled four times and averaged, because a single hole is not a sample. A burr height reported without its measuring method is a claim and not a measurement. HEIDENHAIN notes that dial gauges are enough to run the axis drift test of ISO/DIS 230-3, at reasonable cost. The axis moves repeatedly between points near the ends of its travel, and each position is read until the drift levels off. A ring gauge of known diameter calibrates the ball radius of a machine probe. A GO thread plug gauge checks a tapped hole against its maximum material limit.Read More
Required Accuracy
A gauge has to resolve much less than the tolerance it checks. Lockheed Martin UK’s guidebook asks for equipment accuracy at least 10 times finer than the accuracy required. It points to gauge repeatability and reproducibility studies as the proof. Where an instrument is rejected, the guidebook says the reviewer lacked confidence that a valid, repeatable and reproducible measurement was possible. The 10 times rule is Lockheed’s own, and other buyers set their own ratios, so an order names the rule that applies.Thread Check
ISO 965-2 checks a coated internal thread with a GO plug gauge. At the specified torque, or a lower one, the gauge has to pass through the finished thread. A plug gauge answers one question, whether the thread sits at or inside its maximum material limit. The public preview of the standard does not reproduce the NO-GO rules. Tolerance classes apply before coating unless stated, so the gauge after coating checks that the coating did not push the thread past its limit. MIL-A-8625 explains why that matters: a coating raises the pitch diameter of a 60 degree thread by four times its growth. A buyer who wants the pitch diameter as a value in micrometers asks for it on the inspection plan, and the shop names the method.Temperature Effect
An aluminum bore that passes at the machine can fail at the gauge on a warm afternoon. A 25 mm (0.98 in.) aluminum feature that warms by 20 °C (36 °F) grows 11.8 µm (0.0005 in.). That is 91 % of the IT6 band for its size. Shops that hold small tolerances on aluminum let the part and the gauge rest at room temperature before the check. The drawing or the inspection plan states the temperature, so the reading can be repeated.Report Entry
ISO 2768 states limits and no method of checking. A first article report measures each dimension against its limit with a gauge or a coordinate measuring machine. The report names the gauge or the machine used for each row. For a default dimension that is questioned, it can also name the class and the size row of the table. A nominal 30 mm (1.18 in.) feature measuring 30.25 mm (1.191 in.) passes in one row of ISO 2768-m and fails in the next. A reading gauge gives a number, and a fixed gauge gives a verdict. Lockheed Martin UK requires a physical measurement for every note that contains a dimension, so a verdict is not enough there. A feature drawn in 12 places needs 12 recorded values, which can include a range with a maximum and a minimum.Calibration Reference
A gauge ties the machine’s numbers to something outside the machine. A probe’s stored ball radius comes from a ring gauge, so every bore the probe measures is a diameter relative to that ring. A record of the ring gauge’s certificate is therefore part of the evidence behind each probed size. The same logic applies to every gauge on a report, which is why the equipment column of Form 3 names it.