Meaning
Room temperature is the ambient temperature near 20 °C (68 °F) at which parts are measured and most data sheet properties are stated. A part cut warm shrinks to its true size as it cools. A tolerance has a meaning only at a stated temperature, and room temperature is the usual one.Measuring Practice
Before checking small tolerances on aluminum, shops let part and gauge settle to room temperature. A 200 mm (7.87 in.) aluminum part that is 20 °C (36 °F) warmer grows 0.094 mm (0.0037 in.). That is nearly the whole width of a ±0.05 mm (±0.002 in.) band. For stainless, the final check waits until the part reaches room temperature, or it is finished in a temperature-controlled room. The first question for a drawing is at what temperature the part will be measured.Read More
Properties Above It
Cleveland-Cliffs gives typical room-temperature values for 316 of 627 MPa (91 ksi) tensile and 290 MPa (42 ksi) yield. Strength holds near 490 MPa (71.1 ksi) out to 427 °C (800 °F). At 538 °C (1,000 °F), tensile strength has fallen about 17 % and yield about 45 %. A part that has to stay elastic in a hot stream reads the yield column.Baths Near It
In a plating supplier’s summary of the 2013 revision of ASTM A967, two passivation treatments run near room temperature. Nitric 2 runs at 21 to 32 °C (70 to 90 °F) with 20 to 45 % nitric acid. Citric 3 runs at 21 to 49 °C (70 to 120 °F) with 4 to 10 % citric acid. A shop that cannot heat a tank, or a part that should not sit in a hot bath, narrows the choice to those two.